Installation
EN-US · 30.30.01.01963 · 01 · 09/21
37 / 52
NOTE
Incorrect power supply
Destruction of the integrated electronics
4
Operate the product using a power supply unit with protected extra-low voltage
(PELV).
4
The system must incorporate safe electrical cut-off of the power supply in compliance
with EN60204.
4
Do not connect or disconnect the connector under tension and/or when voltage is ap-
plied.
The electrical connection supplies the mini compact ejector with power and communicates with the con-
troller of the higher-level machine using defined outputs.
8.4.1 Connecting the Connection Cable
Establish the mini compact ejector’s electrical connection using plug connector 1 as shown in the figure.
ü
Provide a connection cable with an M8 6-pole socket (customer’s responsibility).
4
Attach the connection cable to the mini com-
pact ejector (maximum tightening torque =
hand-tight).
1
For mini compact ejectors with a JST plug, establish the ejector’s electrical connection using plug connec-
tor 1 as shown in the figure.
ü
Provide a connection cable with a 5-pole JST plug (customer’s responsibility).
4
Attach the connection cable to the mini com-
pact ejector.
1
Ensure that the electrical cable does not exceed the maximum length of 20 meters.