Operating and Menu Concept
EN-US · 30.30.01.02084 · 02 · 12/20
19 / 72
Display
code
Parameter
Possible settings
Explanation
t-1
Max. permissi-
ble evacuation
time
Configurable be-
tween 0.01 and
9.99 s in 0.01 incre-
ments
off
Permissible evacuation time; evaluation in IO-
Link only
No monitoring
-L-
Max. permissi-
ble leakage
Values from 0 to
999 mbar/s can be
configured in
1 mbar/s increments
Menu item only displayed when
ctr
=
On5
Unit: millibar per second
This value is used for onS and CM warnings. The
adjustable leakage value can be used to judge
the quality of the suction process. Evaluation in
IO-Link only.
bLo
Blow off func-
tion
-E-
1-t
E-t
Externally controlled
Internally controlled (triggered internally, time
can be set)
Externally controlled (triggered externally, time
can be set)
o-2
Signal output 2
no
nc
Configure output 2, “Part Present” check
for normally open
for normally closed
tYP
Signal Type
PnP
nPn
Define signal type for inputs and outputs
Signal type PNP, input/output on = 24 V
Signal type NPN, input/output on = 0 V
dLY
H2 switching
signal delay
Values:
10
,
50
,
200
and
oFF
Delays the switching signals
X1
and
X2
Unit: milliseconds
uni
Vacuum unit
-bA
-ix
-PA
Define the displayed vacuum unit
Vacuum level in mbar
Vacuum level in inHg
Vacuum level in kPa
dPY
Display rotation
5td
Red
Display configuration
Standard
rotated 180°
Eco
Display in ECO
mode
oFF
on
Configure the display
ECO mode is deactivated – the display remains
on
ECO mode is activated – the display switches off
Pin
PIN
Value from
001
to
999
Specify the PIN, lock the menus
If the PIN is
000
, then the device is not locked.
rE5
Reset
YES
Set all parameter values to factory settings.
The factory settings for the parameters are listed in the Technical Data section.