Installation
EN-US · 30.30.01.02084 · 02 · 12/20
43 / 72
NOTE
Incorrect power supply
Destruction of the integrated electronics
4
Operate the product using a power supply unit with protected extra-low voltage
(PELV).
4
The system must incorporate safe electrical cut-off of the power supply in compliance
with EN60204.
4
Do not connect or disconnect the connector under tension and/or when voltage is ap-
plied.
NOTE
Power load too high
Destruction of the vacuum switch, as there is no protection against overloading!
4
Prevent constant load currents > 0.1 A.
The electrical connection is established using a 5-pin M12 connector that supplies the vacuum switch with
voltage, and contains the two input signals and the output signal. The inputs and outputs are not electri-
cally isolated from one another.
The maximum line length for the supply voltage, the signal inputs and the signal output is:
•
30 m in SIO mode
•
20 m in IO-Link mode
Connect the ejector electrically using the plug connection 1 shown in the figure
1
1
Electrical connection plug, M12, 5-pin
ü
Prepare a connection cable with an M12 5-pin connector (supplied by the customer).
4
Attach the connection cable to the electrical connection (1) on the ejector (max. tightening torque =
hand-tight).