17 Attachment
See also
2
SCPSi_V2 Data Dictionary 21.10.01.00065_02 2014-08-29.pdf [
17.1 Overview of the Display Codes
Code
Parameter
Comment
x-1
Limit value H1
Switch-off value for air-saving function/control
h-1
Hysteresis value h1
Hysteresis of control
x-2
Limit value H2
Switch-on value of the “Part Present” signal output (when the NO
output is configured)
h-2
Hysteresis value h2
Hysteresis of “Part Present” check signal output
tbL
Blow off time
Set the blow off time for time-controlled blow off
CAL
Zero-point adjustment
Calibrating the vacuum sensor
cc1
Total counter 1
Counter for suction cycles (“suction” signal input)
cc2
Total counter 2
Counter for valve switching frequency
5oc
Software function
Displays the current software version
Type
Part number
Displays the part number of the ejector
5nr
Serial number
Displays the serial number of the ejector
Ctr
Energy-saving function
(control)
Setting the control function
on5
Control function on
with leakage monitor-
ing
Control with leak monitoring active
dc5
Deactivate auto. con-
trol shutoff
Suppresses the automatic valve protection function when set to
YE5
.
Cannot be activated when
Ctr
=
off
.
t-1
Evacuation time
Set the maximum permitted evacuation time
-L-
Leakage value
Set the maximum permitted leakage
bLo
Blow off function
Menu for configuring the blow off function
-E-
“External” blow off
Selection of externally controlled blow off
J-t
“Internal” blow off
Select internally controlled blow off (triggered internally, time-ad-
justable)
E-t
“External time-con-
trolled” blow off
Selection of externally controlled blow off (triggered externally;
time-adjustable)
o-2
Signal Output
Menu for configuring the signal output
no
Normally open contact
Setting of the signal output as a normally open contact
nc
Normally closed contact
Setting of the signal output as a normally closed contact
tYP
Signal Type
Menu for configuration of the signal type (NPN/PNP)
PnP
PNP signal type
All input and output signals switch according to PNP (input / out-
put on = 24 V)
nPn
NPN signal type
All input and output signals switch according to NPN (input / out-
put on = 0 V)
uni
Vacuum unit
Setting the vacuum unit
-bA
Vacuum level in mbar
The displayed vacuum is shown in mbar.
-PA
Vacuum level in kPa
The displayed vacuum level is shown in kPa.