Attachment
60 / 72
EN-US · 30.30.01.02084 · 02 · 12/20
Code
Parameter
Comment
-iH
Vacuum level in inHg
The displayed vacuum is shown in inches of Hg.
dLY
Switch-off delay
Setting the switch-off delay for OUT2 (delay)
dPY
Display rotation
Setting the display position (rotation)
5td
Default display
Display is not rotated
Red
Rotated display
Display is rotated by 180°
Eco
ECO mode
Setting ECO mode
Pin
PIN
Entry of the PIN for unlocking the menu
Loc
Menu locked
Parameter modification locked.
Unc
Menu unlocked
The buttons and menus are unlocked.
rE5
Reset
All adjustable values are reset to the factory settings.
17.2 EC Conformity
EU Conformity Declaration
The manufacturer Schmalz confirms that the product Ejector described in these Operating instructions ful-
fills the following applicable EU directives:
2014/30/EU
Electromagnetic Compatibility
2011/65/EU
RoHS Directive
The following harmonized standards were applied:
EN ISO 12100
Safety of machinery — General principles for design — Risk assessment and
risk reduction
EN 61000-6-3+A1+AC
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission
standard for residential, commercial and light-industrial environments
EN 61000-6-2+AC
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity
for industrial environments
EN IEC 63000
Technical documentation for the assessment of electrical and electronic
products with respect to the restriction of hazardous substances
The EU Declaration of Conformity valid at the time of product delivery is delivered with prod-
uct or made available online. The standards and directives cited here reflect the status at the
time of publication of the Operating instructions.