IO-Link Data Dictionary
SCPSi series
21.10.01.00065/02
29.08.2014
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
130
0x0082 Exx
1 byte
ro
1-99 = Error code displayed by the device
140
0x008C cc1
4 bytes
ro
Total number of suction cycles
141
0x008D cc2
4 bytes
ro
Total number of times the suction valve has been switched on
146.0
0x0092
1 Bit
ro
1 = Valve protection active
146.1
0x0092
1 Bit
ro
1 =Evacuation time t1 above limit [t-1]
146.2
0x0092
1 Bit
ro
1 = Leakage rate above limit [-L-]
146.3
0x0092
1 Bit
ro
1 = H1 not reached in suction cycle
146.4
0x0092
1 Bit
ro
1 =Free-flow vacuum > (H2-h2) but < H1
146.5
0x0092
1 Bit
ro
1 = Primary voltage US outside of optimal range
146.6
0x0092
1 Bit
ro
unused
146.7
0x0092
1 Bit
ro
1 = Input pressure outside of operating range
147
0x0093
1 byte
ro
0 = no actual value
1 = Leakage of last suction cycle is >200mbar/s
2 = Leakage of last suction cycle is between 133 … 200mbar/s
4 = Leakage of last suction cycle is between 67 ... 133mbar/s
8 = Leakage of last suction cycle is <67mbar/s
148
0x0094
2 bytes
ro
Time from start of suction to H2 (unit: 1 ms)
149
0x0095
2 bytes
ro
Time from H2 to H1 (unit: 1 ms)
155
0x009B
1 byte
ro
Air consumption of last suction cycle (unit: 1 %)
156
0x009C
2 bytes
ro
Air consumption of last suction cycle (unit: 0.1 Nl)
157
0x009D
2 bytes
ro
Energy consumption of last suction cycle (unit: 1 Ws)
Condition monitoring
Condition monitoring
Condition monitoring
Valve operating counter
Condition monitoring
Condition monitoring
Condition monitoring
Air consumption per cycle
Active error code
Condition monitoring
Counter
Vacuum-on counter
Evacuation time t
1
Energy Monitoring [EM]
Condition Monitoring [CM]
Leakage area
Energy consumption per cycle
Evacuation time t
0
Condition monitoring
Error
Diagnosis
Air consumption per cycle in percent
J. Schmalz GmbH
6 of 11
SCPSi Data Dictionary