IO-Link Data Dictionary
SCPSi series
21.10.01.00065/02
29.08.2014
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
Remark
Counter value cc1 of when the entry was recorded
Bytes 12…17
Bytes 223…228
Remark
Entry 3
Entry 38 (oldest)
Buffer of 38 entries (newest to oldest) with encoding as in ISDU 131
Remark
Single entry was written incorrectly - do not evaluate
Remains until next power-on
Remains until next power-on
Error E03: Vacuum sensor calibration failed
0x1201
Notification: Manual mode exited
Notification: Corrupted entry
Error E01: Internal Error
Description
Encoding of Diagnostic-Type
Diagnostic-Type
Bytes 2…5
0x1207
0x1208
0x1404
Notification: Vacuum sensor calibrated successfully
Notification: Diagnostic buffer cleared
Notification: Parameters restored to factory defaults
…
0x1403
…
0x1203
0x0207
0x1405
Notification: Manual mode entered
0x1202
Errors
0x0405
Error E02: Internal Error
Error E07 appeared: Primary voltage US too low
Data Format of Single Entry (ISDU 132)
Diagnostic-Type (MSB first)
Bytes 0…1
Entry 1 (newest)
Entry 2
Counter cc1 (MSB first)
Data Format of Diagnostic Buffer (ISDU 131)
Notifications
0x1401
0x1402
Notification: Device powered on
Error E07 disappeared: Primary voltage US too low
Error E08 appeared: IO-Link communication interrupted
0x14AA
Diagnostic Buffer - Details
Bytes 0…5
Bytes 6…11
J. Schmalz GmbH
9 of 11
SCPSi Data Dictionary