Description of Functions
EN-US · 30.30.01.01963 · 00 · 05/19
25 / 52
In manual mode, the “suction” and “blow off” ejector functions can be controlled independently of the
higher-level controller using the buttons on the foil keypad of the operating element. This function is
used, among other things, to detect and eliminate leaks in the vacuum circuit.
In this operating mode, the “SP1” and “SP2” LEDs both flash.
Activating Manual Mode
NOTE
Manual mode modified by external signals
Personal injury or damage to property due to unpredictable work steps
4
Ensure that the danger zone of the system is clear of people during operation.
ü
The ejector is on the measurement screen.
4
Press and hold the
and
buttons simultaneously for at least 3 seconds.
ð
The “SP1” and “SP2” LEDs flash.
Deactivating Manual Mode
ü
The ejector is in “manual mode”.
4
Briefly press the
and
buttons at the same time.
ð
The SP1 and SP2 LEDs cease to flash.
The device also exits manual mode when the status of the external signals changes.
When the ejector receives an external signal, it switches to automatic mode.
Activating and Deactivating Manual Suction
Activating manual suction
ü
The ejector is in “manual mode”. The SP1 and SP2 LEDs flash.
4
Press the
button to activate “suction” mode.
ð
The suction LED S lights up.
ð
The ejector begins to suck.
Deactivating manual suction
ü
The ejector is in “suction” mode.
4
Press the
button again.
ð
The suction process is deactivated.
4
Alternatively, press the
button.
ð
The ejector changes to the “blow off” state for as long as you press the button.
If the controller is on [
ctr
] = [
on
] it uses the configured limit values in “manual” mode as well.