4 Technical Data
4.1 Display Parameters
Parameter
Value
Unit
Note
Display
3
Digit
Red 7-segment LED display
Resolution
±1
mbar
--
Accuracy
±3
% FS
T
amb
= 25° C, based on FS final value (full-scale)
Display refresh rate
5
1/s
Only affects the 7-segment display
Idle time before the
menu is exited
1
min
The display mode is accessed automatically when no set-
tings are made in a menu.
4.2 General Parameters
Parameter
Type
Symbol
Limit value
Unit
Note
min.
typ.
max.
Working tempera-
ture
T
amb
0
—
50
° C
—
Storage tempera-
ture
T
Sto
-10
—
60
° C
—
Humidity
H
rel
10
—
85
% r.h.
Free from condensa-
tion
Degree of protec-
tion
—
—
—
IP40
—
—
Operating pres-
sure (flow pres-
sure)
03 and 05
P
2
4
6
bar
—
07 and 10
P
3
4
6
bar
—
Operating
medium
Air or neutral gas, filtered to 5 µm, without oil, class 3-3-3 compressed air quality
in acc. with ISO 8573-1
4.3 Electrical Parameters
Supply voltage
DC 24 V ± 10% (PELV
1)
)
Polarity reversal protec-
tion
Yes
Current consumption
(at 24 V)
—
Typical current consump-
tion
Max. current consump-
tion
SCPMc – xx – NO
50 mA
70 mA
SCPMc – xx – NC
75 mA
115 mA
1)
The power supply must correspond to the regulations in accordance with EN60204 (protected extra-low