Operating and Menu Concepts
20 / 52
EN-US · 30.30.01.01963 · 00 · 05/19
5.1.2 Displaying the basic settings (slide show)
When you press the
button from the home screen, the following parameters are automatically dis-
played one after the other on the display (slide show):
•
The vacuum unit
•
The value of the switching point SP1
•
The value of reset point rP1
•
The value of switching point SP2
•
The supply voltage US
The display cycle returns to the vacuum display after a complete cycle or can be canceled at any time by
pressing any button.
5.2 Main Menu
All settings for standard applications can be accessed and configured using the main menu.
5.2.1 Functions in the Main Menu
The following table shows an overview of the display codes and parameters in the main menu:
Display
code
Parameter
Explanation
5P1
Switching point 1
Value at which the control function deactivates
(only active if [
ctr
] = [
on
])
rP1
Reset point 1
Reset value 1 for the control function
5P2
Switching point 2
Switching value for the “Parts control” signal
rP2
Reset point 2
Reset value 2 for the “Parts control” signal
tbL
Blow off time
Blow off time setting for time-controlled blow off (only active if
value > 0)
CAL
Zero-point adjust-
ment (calibration)
Calibrate vacuum sensor, zero point = ambient pressure
EF
Extended functions
Open the “Extended Functions” submenu
1mF
Information
Open the “Information” submenu
1nc
Incorrect
The entered value is not within the permissible value range.
This is an informational message that appears if incorrect informa-
tion is entered.
5.2.2 Changing the Parameters of the Main menu
If you wish to change values, e.g. the switching points, you have to enter the new value digit by digit.
1. Use the
button to select the desired parameter.
2. Confirm using the
button.
ð
The currently set value is displayed and the first digit flashes.
3. Use the
button to change the value. The value increases by 1 each time the button is pressed.
After 9, the counter goes back to 0 when the
button is pressed.
4. Press the
button to save the modified value.
ð
The first digit is accepted and the second digit flashes.