Description of Functions
24 / 52
EN-US · 30.30.01.01963 · 00 · 05/19
6 Description of Functions
6.1 Overview of Functions
Description
Parameter
See section
Operating modes
—
(> See ch. Operating Modes, Page 24)
Automatic operation and manual operation
Switching point setting
5P1
/
rP1
5P2
/
rP2
(> See ch. Monitoring the system vacuum and defin-
ing limit values, Page 26)
Calibrate zero point
CAL
(> See ch. Calibrating the sensor, Page 26)
Energy-saving function, control
function
ctr
(> See ch. Control functions, Page 26)
Define blow off time
tbL
(> See ch. Blow off modes, Page 27)
Display unit
uni
(> See ch. Selecting the display unit, Page 27)
Reset to factory settings
rE5
(> See ch. Reset to factory settings, Page 28)
Counter(s)
cc1
cc2
Software version
5oc
(> See ch. Displaying the software version, Page 29)
Article/part number
Art
(> See ch. Displaying the part number, Page 29)
Serial number
5nr
(> See ch. Displaying the serial number, Page 30)
Condition monitoring (CM)
t-1
-L-
(> See ch. Condition Monitoring (CM), Page 31)
Optional: external blow off
Compressed air connector 1A
—
(> See ch. Optional: External blow-off connection
(EB), Page 37)
Error messages
e.g.
E03
FFF
-FF
(> See ch. Error messages, Page 42)
6.2 Operating Modes
6.2.1 Automatic Mode
Once the ejector is connected to the power supply, it is ready for operation and enters automatic opera-
tion mode. This is the normal operating mode, in which the ejector is operated by the system controller.
The operating mode may be changed from automatic to manual mode using the buttons.
Parameterization of the ejector is always performed in automatic mode.
6.2.2 Manual Mode
NOTE
Change the output signals in manual mode
Personal injury or damage to property
4
Electrical connection may be performed only by specialists who can judge the effects of
signal changes on the overall system.