Installation
EN-US · 30.30.01.01963 · 00 · 05/19
37 / 52
8.3.3 Optional: External blow-off connection (EB)
The ejector is also optionally available with an additional compressed air connector for the blow off func-
tion.
With the external blow off function (EB), the blow off pulse is controlled separately and independently of
the compressed air supply for vacuum generation, allowing you to use a different medium (e.g. nitrogen)
for the blow off function.
It also allows you to precisely set the blow off pressure using an external pressure regulator (between 2
and 6 bar).
The blow off flow rate can also be set between 0% and 100% directly on the ejector. This can be used, for
example, to set down small and lightweight workpieces with high positioning precision.
The hose size and the thread on the connector depend on the particular ejector and can have the follow-
ing dimensions:
•
Push-in: 4/2
•
M5 female thread
4
Connect the compressed air hose for external
blow off (connector marked with 1A) and ad-
just the blow off flow rate using the adjusting
screw (2).
1A
2
8.4 Electrical Connection
NOTE
Change of output signals when product is switched on or plug is connected
Personal injury or damage to property
4
Electrical connection may be performed only by a qualified specialist who can predict
the effects that signal changes will have on the entire system.
NOTE
Incorrect power supply
Destruction of the integrated electronics
4
Operate the product using a power supply unit with protected extra-low voltage
(PELV).
4
The system must incorporate safe electrical cut-off of the power supply in compliance
with EN60204.
4
Do not connect or disconnect the connector under tension and/or when voltage is ap-
plied.