Installation
38 / 52
EN-US · 30.30.01.01963 · 00 · 05/19
The electrical connection supplies the ejector with power and communicates with the control system of
the higher-level machine using defined outputs.
Establish the ejector’s electrical connection using plug connector 1 as shown in the figure.
ü
Provide a connection cable with an M8 6-pole socket (customer’s responsibility).
4
Attach the connection cable to the ejector,
maximum tightening torque = hand-tight.
1
For ejectors with a JST plug, establish the ejector’s electrical connection using plug connector 1 as shown
in the figure.
ü
Provide a connection cable with a 5-pole JST plug (customer’s responsibility).
4
Attach the connection cable to the ejector.
1
Ensure that the electrical cable does not exceed the maximum length of 20 meters.
8.4.1 Pin assignments
M8 plug
Pin
Symbol
Wire color
1)
Function
1
US
Brown
24 V power supply
2
IN1
White
“Suction” signal input
3
GND
Blue
Ground
4
OUT
Black
“Parts control” output (SP2)
5
IN2
Gray
“Blow off” signal input
6
—
Pink
Not used
1)
When using a Schmalz connection cable, part no. 21.04.05.00488 (see accessories)