Interfaces
40 / 94
EN-US · 30.30.01.02237 · 00 · 04/20
Device Monitoring Parameters
Offset
Index
Description
Type
Length
[bytes]
R/W
(Dec)
(Hex)
66
0x0042
0
Primary supply voltage
uint16
2
ro
66
0x0042
1
Primary supply voltage, min.
uint16
2
ro
66
0x0042
2
Primary supply voltage, max.
uint16
2
ro
67
0x0043
0
Auxiliary supply voltage
uint16
2
ro
67
0x0043
1
Auxiliary supply voltage, min.
uint16
2
ro
67
0x0043
2
Auxiliary supply voltage, max.
uint16
2
ro
148
0x0094
0 … 15
Evacuation time t0 for ejectors #1 to #16
uint16
16 x 2
ro
149
0x0095
0 … 15
Evacuation time t1 for ejectors #1 to #16
uint16
16 x 2
ro
156
0x009C
0 … 15
Air consumption per cycle for ejectors #1 to #16
uint32
16 x 4
ro
156
0x009C
16
Air consumption per cycle of all ejectors
uint32
4
ro
160
0x00A0
0 … 15
Leakage rate for ejectors #1 to #16
uint16
16 x 2
ro
161
0x00A1
0 … 15
Free-flow vacuum for ejectors #1 to #16
uint16
16 x 2
ro
164
0x00A4
0 … 15
Max. vacuum reached in cycle for ejectors #1 to
#16
uint16
16 x 2
ro
515
0x0203
0 … 15
System vacuum for ejectors #1 to #16
uint16
16 x 2
ro
11000
...
11015
0x2AF8
...
0x2B07
0
Ejector extended values #1 to #16
uint16
16 x 2
ro
Device Diagnostics Parameters
Offset
Index
Description
Type
Length
[bytes]
R/W
(Dec)
(Hex)
10
0x000A
0
Device status [part of processdata]
uint8
1
ro
130
0x0082
0 … 15
Errors in ejectors #1 to #16
uint8
16 x 1
ro
130
0x0082
16
CU active errors [part of processdata] (active er-
rors of control unit)
uint8
1
ro
138
0x008A
0
Extended device status – event category
uint16
1
ro
138
0x008A
1
Extended device status – event code
uint16
1
ro
139
0x008B
0
NFC status
uint8
1
ro
32
0x0020
0
IO-Link communication status
uint8
2
ro
140
0x008C
0 … 15
Vacuum-on counter for ejectors #1 to #16
uint32
16 x 4
ro
141
0x008D
0 … 15
Valve operating counter for ejectors #1 to #16
uint32
16 x 4
ro
143
0x008F
0 … 15
Erasable vacuum-on counter for ejectors #1 to
#16
uint32
16 x 4
ro
144
0x0090
0 … 15
Erasable valve operating counter for ejectors #1
to #16
uint32
16 x 4
ro
146
0x0092
0 … 15
Condition monitoring of ejectors #1 to #16
uint8
16 x 1
ro
146
0x0092
16
CU condition monitoring [part of processdata]
(condition monitoring of control unit)
uint8
1
ro