Component Functions
58 / 94
EN-US · 30.30.01.02237 · 00 · 04/20
Default value
0x00
Unit
-
EEPROM
-
Offset parame-
ter
10609 (0x2971)
Refers to IO-Link master 1 – Port X1
10610 (0x2972)
Refers to IO-Link master 1 – Port X1
Description
Event code
Event source
Event number
Evacuation time t1 for ejectors
Index
-
Data type
uint16
uint8
Length
2 bytes
2 bytes
Access
Read only
Value range
See “Extended Device Status – Event
Code” --> 6.3.1 “Device Diagnostics”
0 … 65535
Default value
0x00
Unit
-
EEPROM
-
NFC Status (0x008B)
This parameter is used to determine the current status of the NFC data transfer.
Offset parame-
ter
139 (0x008B)
Description
NFC status
Index
-
Data type
uint8
Length
1 bytes
Access
Read only
Value range
0x00: data valid, write finished successfully
0x23: write failed: write access locked
0x30: write failed: parameter(s) out of range
0x41: write failed: parameter set inconsistent
0xA1: write failed: invalid authorization
0xA2: NFC not available
0xA3: write failed: invalid data structure
0xA5: write pending
0xA6: NFC internal error
Default value
-
Unit
-
EEPROM
no
Transferring Device Data with NFC
The reading distance is very short for NFC applications. If necessary, find the position of the
NFC antenna in the reading device used.
ü
Use a suitable read/write device with activated NFC, such as a smartphone or tablet.
1. Align the read device as parallel to the top of the SCTSi as possible.
2. Position the antenna of the read device in the center of the SCTSi’s antenna.