Installation
80 / 94
EN-US · 30.30.01.02237 · 00 · 04/20
8.3 Connecting the Compressed Air and Vacuum
CAUTION
Compressed air or vacuum in direct contact with the eye
Severe eye injury
4
Wear eye protection
4
Do not look into compressed air openings
4
Do not look into the silencer air stream
4
Do not look into vacuum openings, e.g. suction cups
CAUTION
Noise pollution due to incorrect installation of the pressure and vacuum connec-
tions
Hearing damage
4
Correct installation.
4
Wear ear protectors.
1
2
3
1
1x compressed air connection per 16 ejec-
tor discs
2
Optional: Compressed air connection
3
1x vacuum air connection per ejector disc
(marking 2)
The compressed air connector with the plug connector 8/6 or 1/8” thread is marked with the number 1 on
the ejector disc.
4
Connect compressed air hose. For threaded connectors, the maximum tightening torque is 1 Nm.
The vacuum connector with the plug connector 8/2 or 6/4 or M5 or M7 thread is marked with the number
2 on the ejector disc.
4
Connect the vacuum hose. For threaded connectors, the maximum tightening torque is 1 Nm.
8.3.1 Recommended Line Cross Sections (Internal Diameters) in mm
SCPS performance
class
Cross section, compressed
air-side
For 2 to 8 ejectors
1)
Cross section, compressed
air-side
For 9 to 16 ejectors
1)
Cross section, vac-
uum side
1)
07
7
9
4
10
7
9
4
15
7
9
6
2-07
7
9
4