Installation
EN-US · 30.30.01.02237 · 00 · 04/20
81 / 94
SCPS performance
class
Cross section, compressed
air-side
For 2 to 8 ejectors
1)
Cross section, compressed
air-side
For 9 to 16 ejectors
1)
Cross section, vac-
uum side
1)
2-09
7
9
4
2-14
7
9
6
1)
Specifications based on a maximum hose length of 2 m.
4
For longer hose lengths, the cross sections must also be larger.
If the recommended line cross section is too large due to how the line is routed (e.g. an energy chain or
robot flange), the alternative compressed air connections can be used to provide additional compressed
air.
8.4 Electrical Connection
NOTE
Change of output signals when product is switched on or plug is connected
Personal injury or damage to property
4
Electrical connection may be performed only by specialists who can evaluate the effects
of signal changes on the overall system.
NOTE
Incorrect connection with the IO-Link class B port
Damage to the IO-Link master or periphery
4
When operating the IO-Link class A switch with an IO-Link master with a class B port,
ensure compliant connection and potential separation.
NOTE
Incorrect power supply
Destruction of the integrated electronics
4
Operate the product using a power supply unit with protected extra-low voltage
(PELV).
4
The system must incorporate safe electrical cut-off of the power supply in compliance
with EN60204.
4
Do not connect or disconnect the connector under tension and/or when voltage is ap-
plied.
NOTE
Power load greater than 16 A
Damage to the device
4
Ensure that the maximum permissible total current (for the whole terminal) of 16 A is
not exceeded.
4
In addition, suitable fuse protection of the supply line is necessary.
4
The supply line must be designed in accordance with the planned power consumption
and the length of the line. A cable cross-section of 2.5 mm² is recommended.