56 | EN
www.schmalz.com
30.30.01.01648/06
11 Pneumatic Circuit Diagram
Before initiating the blow off pulse, ensure that the gripper (with attached workpiece) is not pressed
against a solid surface. The workpiece must be able to freely detach from the gripper.
Maximum overpressure
The maximum overpressure in the gripper (vacuum reservoir or valve chamber)
must be limited to a maximum of 0.2 bar.
Pneumatic Circuit Diagram of the Standard Version FMHD
FMHD with separating cylinder and “Blow off” function
“Blow off ON/OFF” con-
trol valve
“Separating cylinder
ON/OFF” control valve
Function integrated in
the end cover
Vacuum area gripper
Check valve displayed
Separating
cylinder
Vacuum generator, to be
provided by the customer
Compressed air source to be provided
by the customer (flow pressure 6.0
bar)