44 | EN
www.schmalz.com
30.30.01.01648/06
WARNING
System maintenance by untrained personnel
Serious personal injury
► The system must only be set up by trained personnel who have read and un-
derstood the operating instructions.
DANGER
General safety notes on maintenance
Danger to life and limb
► The system integrator must secure the danger zone.
►
The production system must be stopped in the area where the system is being
maintained.
►
The system may only be maintained in accordance with the operating instruc-
tions.
► The system must be disconnected and depressurized during maintenance.
►
The production system must be secured to prevent activation during mainte-
nance work.
Human error
Danger to life and limb
► Adhere to the instruction manual
Remove any dirt on the exterior with a soft cloth and soap suds (max. 60 °C).
Operation of the area gripper can draw in dust from the environment. This dust can collect inside the
gripper. The gripper must be cleaned regularly, depending on the amount of dust sucked in.
Maintenance Schedule
Maintenance and cleaning may only be carried out by trained specialist personnel or by the manufac-
turer.
We recommend checking the contamination within the suction bar for the first time in the first month af-
ter start of operations.
Interval
Daily Weekly Monthl
y
Every six
months
Annual
inspec-
tion
Does the vacuum generator make strange noises when
a full load is picked up?
X
Has the dust filter been cleaned?
X
Is the electrical installation still okay? Is the cable screw
union secure?
X
Are the vacuum hoses in good condition (not brittle, not
kinked, no worn sections and no leaks)?
X
Check that all the connections are secure, e.g. the
screws, hose clamps, etc.
X
Are the type plate and maximum load plate still attached
to the device?
X