30.30.01.01648/06
www.schmalz.com
EN | 45
Are the operating instructions available and are the sys-
tem operators familiar with them?
X
Check all load-bearing parts (e.g. suspension eyes) for
deformation, wear, or other damage.
X
Check the sealing mats for wear, tears and leaks. Re-
place if necessary.
X
General condition of the device
X
Leak test
X
Check reservoir/suction chamber and ball valves for dirt
The interval depends on the applica-
tion/ambient conditions.
External Vacuum Generator
See the relevant operating instructions.
Dust Filter
When using a dust filter, see the relevant operating instructions.
Cleaning Agents
Use cleaning solvents to clean the device (not petroleum ether or corrosive liquids. Petroleum ether or
corrosive liquids destroy the vacuum hoses).
Quick-change Plate
To make maintenance easier and replace the foam more quickly, the quick-change plate is integrated into
the gripper as standard. In order to reduce downtime, a second, identical plate can be made available
during maintenance and used to replace the contaminated plate. See Section 9.9