Product Description
12 / 96
EN
· 30.30.01.02851 · 01 · 03/22
FMP-i Version
On the version for external vacuum generators, the valve is opened using the suction command. This ensures that the
vacuum reaches the inside of the gripper so that products can be lifted.
•
In the NO (normally open) variant, the valve is closed when the suction signal is received.
•
In the NC (normally closed) variant, the valve is opened when the suction signal is received.
An integrated sensor measures the vacuum. The exact vacuum level is shown on the display and can be read from the
IO-Link process data.
The air saving function is not available for the FMP-i version. The valve is controlled exclusively via signals.
3.2.1
Setting Down the Load
In blow-off mode, the ejector is deactivated and the valve is closed, and the inside of the gripper is supplied with
compressed air. This ensures that the vacuum drops quickly, thereby depositing the workpiece quickly.
During blow-off, [-FF] is shown on the display.
The gripper provides three blow off modes for selection:
•
Externally controlled blow off
•
Internally time-controlled blow off
•
Externally time-controlled blow off
•
Optional: external blow off
3.2.2
Description of Functions: Valve Technology SVK
NOTE
Tilting the area gripper with SVK technology
Limitations of the functionality
The valve technology SVK functions optimally when the gripper is used exclusively horizontally.
•
Maximum permitted swivel angle relative to the horizontal: 60°.
•
Maximum permitted acceleration in the vertical direction: 5 m/s².
•
It is not possible to provide additional suction or pick up other products later.