Operating and Menu Concept
The area gripper is operated using two buttons on the foil keypad.
MENU BUTTON
PLUS BUTTON
Navigation is divided into three menus:
•
The main menu: for standard applications
•
The Extended Functions (EF) menu: for applications with special requirements
•
The Info menu (INF): for reading out system data such as counters, the software version, etc.
If settings are changed, undefined states of the system may occur for a short time (for approx. 50 ms).
The following information can be shown on the display:
•
The current vacuum measurement value
•
The selected menu item
•
The settings
•
Error messages in the form of error codes
The operating menu’s home screen shows the currently measured vacuum level in the selected display unit. The
available units are millibar, kilopascal, inHg and psi. The measured value is displayed as positive compared to the
ambient air pressure.
The menus will automatically close if no buttons are pressed for 1 minute.
The display also returns to the home screen when an error occurs so that the error code can be displayed. A menu can
be called up and used again afterward.
5.1
Button Assignments in Display Mode
In display mode, a specific function is assigned to each key.
5.1.1
Opening the Menu
Press the PLUS BUTTON opens the following menus:
Press the
button briefly.
The main menu opens with the first parameter
.
Opening the EF menu for extended functions:
1.
Press the
button several times until the parameter
appears on the display.
2.
Press the
button to switch to the EF submenu for extended functions.