Operating and Menu Concept
36 / 96
EN
· 30.30.01.02851 · 01 · 03/22
Display
code
Parameter
Possible settings
Explanation
Max. permissible
evacuation time
configurable between
0.01 and 9.99 seconds
in steps of 0.01
Permitted evacuation time
No monitoring
Max. permissible
leakage
Values from
to
can be set
Permitted leakage
Unit: millibar per second
Blow off function
Externally controlled
Internally controlled (triggered internally, time can be
set)
Externally controlled (triggered externally, time can be
set)
Output function
Normally open contact
Normally closed contact
Output type
Output
PNP switch
NPN switch
Switching signal
delay
Value from
to
can be set
Delay between switching signals SP1 and SP2 in
milliseconds
Vacuum unit
Define the displayed vacuum unit
Vacuum level in millibar [mbar]
Vacuum level in kilopascal [kPa]
Vacuum value in inch of mercury [inHg]
Vacuum value in pound-force per square inch [psi]
Display rotation
Display configuration
Standard
rotated 180°
Display in ECO
mode
Set the display
ECO mode is deactivated – the display remains on
The brightness is reduced by 50 percent.
Eco mode activated – if no buttons are pressed, the
display turns off after one minute
PIN code
Value from
to
Specify the PIN code, lock the menus
If the PIN code is
the device is not locked.
NFC lock
NFC lock:
NFC active
Completely switched off
Write-protected
Reset
The values remain unchanged
Reset parameter values to factory settings