Description of Functions
50 / 96
EN
· 30.30.01.02851 · 01 · 03/22
Confirm the parameter by pressing the
button.
The first three decimal places of the counter total are displayed (the digits x 106). This corresponds to the
three-digit block with the highest value.
Use the
button to display the remaining decimal places of the counter total, in order of descending value. The
decimal points show which 3-digit block of the counter total is shown in the display.
The counter total is comprised of the 3-digit blocks taken together:
Displayed section
10
6
10
3
10
0
Digit block
The current counter total in this example is 48 618 593.
Non-erasable counter readings are saved only every 1000 steps. That means that when the operating
voltage is switched off, up to 999 counter steps are lost.
Erasing counters [0x0002]
There are two different ways of resetting the erasable counters Ct1, Ct2 and Ct3 to 0:
•
Using system commands via IO-Link
•
Using the control panel:
The
menu is open.
1.
Use the
button to select the parameter
.
2.
Confirm using the
button.
3.
Use the
button to select the setting parameter
.
4.
Confirm using the
button.
The erasable counters Ct1, Ct2 and Ct3 are set to 0.
7.17
Displaying the Software Version
The software version indicates the software currently running on the internal controller.
The system firmware can be updated using the “Firmware Update” profile defined by IO-Link. If necessary, this will
also update the firmware for the valve module. The PD bit In Byte 1.2 signals when a more recent version is available
in the supply module.
Using the control panel:
The Info menu is open.
1.
Use the
button to select the parameter
.
2.
Confirm using the
button.
The software ID is displayed.
To exit the function, press the
button.