Installation
EN
· 30.30.01.02851 · 01 · 03/22
65 / 96
9.6
Mounting the Ejector Assembly
To make it easier to perform maintenance work, the plug-in ejector that is integrated in the area gripper can be
removed.
1
Control and display unit (figure with optional
pentaprism)
2
Nameplate with QR code
3
Plug-in ejector
4
End cover with control unit
5
Self-tapping fastening screws (4x)
6
Silencer mounting clips
7
Silencer housing
8
Machine screws for retaining clips (4x)
9
Filter
Removing the assembly
1.
Remove the silencer (7).
2.
Loosen the four machine screws (8) with which the retaining clips are mounted.
3.
Loosen the four self-tapping screws (5) on the front.
4.
If necessary, loosen the foam on the underside of the housing cover.
The assembly can be removed.
Installing the assembly
1.
Push the functional module into the main body.
2.
Gently tighten the four screws (8) for attaching the retaining clips for the silencers to the top of the area
gripper (1 Nm) until the screws (5) can be easily inserted on the ejector cover.
3.
Tighten the four fastening screws (5) on the end cover (4) (4 Nm).
4.
Tighten the fastening screw (8) at the top of the area gripper (1.2 Nm).
5.
Clip in the silencer housing.
1
2
4
3
8
5
7
6