INSTALLATION
30.30.01.00176/01
www.schmalz.com
EN | 33
5.4.2 With load
WARNING
Operator handle jolting upward after switching on the vacuum
generation
Risk of injuries
►
Do not set the hovering position on the upper stop (adjusting screw on the
stop).
Turn the adjusting screw (2) on the operator handle
Turn clockwise
hovering position is lowered
Turn counterclockwise
hovering position is raised.
ATTENTION
Hovering position at the end stop (in the top
position)
Damage to the ejector
High energy consumption
► When handling a load, do not set the hovering
position to the top position.
5.5 Test
The installation of the tube lifter is complete after 3 to 4 successful test runs using a
workpiece. The checks required in Europe before the start of operations in accordance
with EN 14238 are covered by a type test.
2