38 | EN
www.schmalz.com
30.30.01.00176/01
6.4.2 With quick-change adapter (optional)
Disassembly:
1. Park the suction cup securely.
2. Switch off the vacuum generator.
3. Raise and hold onto the latching bolts (5) on the operator handle (4).
4. Rotate the suction cup (6) in direction B.
The suction cup detaches from the operator handle and can be removed.
Mounting:
1. Switch off the vacuum generator.
2. Insert the suction cup into the operator handle (A) and rotate the suction cup in direction (B)
until the latching bolt (5) engages in the end position in the designated opening on the gripper.
The vacuum gripper is now secured against automatic opening.
3. Inspect equipotential bonding (see chapter 5.3).
Operator handle with quick-change adapter
Top view of the quick-change adapter
CAUTION
Suction cup not locked in place
Risk of injury from falling parts
►
Ensure that the latching bolt (5) is engaged correctly.
4
6
5
A
B