OPERATION
30.30.01.00176/01
www.schmalz.com
EN | 39
6.5 Switching on the vacuum generator
WARNING
Tube lifter jolting upward uncontrollably
Risk of injuries
Before switching on the vacuum generator, ensure that the suction cup cannot
become attached to a load or the ground below.
1.
Set the operator handle to “Lower/Deposit Load.”
2. Hold the operator handle firmly.
3. Switch on the vacuum generator.
4. Open the ball valve of the compressed air off switch by pulling the black ball knob (8.1).
6.6 Lifting the load
WARNING
Tube lifter jolting upward uncontrollably
Risk of injuries
►
►
Before lifting, ensure that:
The hovering position with and without the load has been set
The load is not stuck or tilted
The maximum system load capacity is not exceeded
The shrink wrapped good is in good condition
Ensure that the load is distributed evenly.
8.1