Technical Data
18 / 68
EN-US · 30.30.01.01961 · 00 · 06/19
NC-EB
NO-EB
5.4.5 Factory Settings
Code
Parameter
Value of the factory setting
5P1
Switching point SP1
750 mbar
rP1
Reset point rP1
600 mbar
5P2
Switching point SP2
550 mbar
rP2
Reset point rP2
540 mbar
tbL
Blow off time
0.20 s
ctr
Control
Activated =
on
dc5
Sustained suction
Deactivated =
off
t-1
Evacuation time
2.00 s
-L-
Leakage value
250 mbar/s
bLo
Blow-off function
Externally controlled blow-off =
-E-
0u2
Output function
Switching logic – output 2 = NO
P-n
Signal type
Output level = PNP
uni
Vacuum unit
Vacuum unit in mbar =
bar
dLY
Switch-off delay
10 ms
dPY
Display rotation
Standard =
5td
Eco
ECO mode
Deactivated =
oFF
P1n
PIN code
User-defined
000
The production setup profiles P-1 to P-3 are factory-set to have the exact same data set as the default
data set P-0.