Installation
50 / 68
EN-US · 30.30.01.01961 · 00 · 06/19
The electrical connection supplies the ejector with power and communicates with the controller of the
higher-level machine using defined outputs or via IO-Link.
Establish the ejector’s electrical connection using plug connector 1 as shown in the figure.
ü
Provide a connection cable with an M8 6-pole socket (customer’s responsibility).
4
Attach the connection cable to the electrical
connection point (1) on the ejector, max.
tightening torque = hand-tight.
1
Ensure that the electrical cable does not exceed the maximum length of 20 meters.
10.4.1 Pin Assignments
M8 plug
Pin
Symbol
Wire color
1)
Function
1
US
Brown
24 V power supply
2
IN1
White
“Suction” signal input
3
GND
Blue
Ground
4
OUT / CQ
Black
“Parts control” output (SP2) or IO-
Link
5
IN2
Gray
“Blow-off” signal input
6
—
Pink
Not used
1)
When using a Schmalz connection cable, part no. 21.04.05.00488 (see accessories)