Product Description
10 / 68
EN-US · 30.30.01.01961 · 00 · 06/19
3 Product Description
3.1 Operating Modes
If the ejector is connected to the supply voltage, it is ready for operation. This is the normal operating
mode, in which the ejector is operated by the system controller.
The ejector is parameterized via the available menus or via IO-Link.
The following operating modes are available during the setup process:
•
Setting mode (only via IO-Link) and
•
Manual mode
3.2 Ejector Designation
The breakdown of the item designation (e.g. SCPMi 10 S04 NC M8-6 BLT) is as follows:
Feature
Variants
Type
SCPM
Version
Intelligent: i
Nozzle size
0.3, 0.5, 0.7 and 1.0 mm
Fluid connector
S01 (push-in, 4/2 2x)
G01 (M5 female 2x)
S04 (push-in, 6/4 2x)
G06 (M7 female 2x)
S07 (push-in, 4/2 3x)
G07 (M5 female 3x)
S08 (push-in, 6/4 2x, 4/2)
G08 (M7 female 2x, M5 female)
S09 (push-in, 4/2, 6/4 2x)
G09 (M5 female, M7 female 2x)
Suction valve control
NO (normally open), sucks when no voltage is applied
NC (normally closed), does not suck when no voltage is applied
Electrical connection
M8 plug, 6-pole
Individual configuration
code
The 3-digit code “AAA” uniquely describes an ejector disk.
3.3 Ejector Structure
9
1
2
3
5
7
8
6
4
1
Compressed air connector (marking 1)
2
Vacuum connection (marking 2)