Description of Functions
36 / 68
EN-US · 30.30.01.01961 · 00 · 06/19
Erasing Counters [0x0002]
There are two different ways of resetting the erasable counters Ct1, Ct2 and Ct3 to 0:
•
Using system commands via IO-Link
•
Using the control panel:
ü
The [
1mf
] menu is open.
1. Use the
button to select the parameter [
rct
].
2. Confirm using the
button.
3. Use the
button to select [
YE5
] for the parameter value.
4. Confirm using the
button.
ð
The erasable counters Ct1, Ct2 and Ct3 are set to 0.
8.17 Displaying the Software Version
The software version indicates the software currently running on the internal controller.
The system firmware can be updated using the “Firmware Update” profile defined by IO-Link. If neces-
sary, this will also update the firmware for the valve module. The PD bit In Byte 1.2 signals when a more
recent version is available in the supply module.
Using the control panel:
ü
The Info menu is open.
1. Use the
button to select the [
5oc
] parameter.
2. Confirm using the
button.
ð
The software ID is displayed.
4
To exit the function, press the
button.
8.18 Displaying the Part Number [0x00FA]
The part number of the ejector is printed on the label and also stored electronically.
ü
The ejector is in the
1mF
menu.
1. Use the
button to select the part number parameter
Art
.
2. Use the
button to confirm the part number parameter
Art
.
ð
The first two digits of the part number are displayed.
3. Press the
button again several times.
ð
The remaining digits of the part number are displayed. The decimal points shown are part of the
part number.
In the first block displayed, the point on the far right (after the second digit), which is part of
the part number, is not displayed for technical reasons.
The part number consists of 4 blocks with a total of 11 digits.
Displayed section
1
2
3
4
Digit block
10
02.0
2.00
383