Technical Data
18 / 74
EN-US · 30.30.01.01598 · 02 · 01/18
4 Technical Data
4.1 Operation and Storage Conditions
Operating medium
Air or neutral gas
5 µm filtered
Oiled or unoiled
Class 3-3-3 compressed air quality acc. to ISO 8573-1
Operating pressure (flow pres-
sure)
2 to 6 bar (optimally 4 to 4.5 bar)
Working temperature
0 to 50 °C
Storage temperature
-10 to 60 °C
Permitted air humidity
10 to 90% RH (free from condensation)
Precision of vacuum sensor
± 3% FS (full scale)
4.2 Electrical Data
Power supply for sensor
24 V -20 to +10% VDC (PELV
1)
)
Power supply for actuator
24 V -20 to +10% VDC (PELV
1)
)
Sensor power consumption
2)
(at 24
V)
SCTMi with 4 NC ejectors
170 mA
SCTMi with 8 NC ejectors
220 mA
SCTMi with 16 NC ejectors
320 mA
SCTMi with 4 NO ejectors
170 mA
SCTMi with 8 NO ejectors
230 mA
SCTMi with 16 NO ejectors
350 mA
Actuator power consumption
2)
(at
24V)
SCTMi with 4 NC ejectors
120 mA
SCTMi with 8 NC ejectors
200 mA
SCTMi with 16 NC ejectors
330 mA
SCTMi with 4 NO ejectors
200 mA
SCTMi with 8 NO ejectors
240 mA
SCTMi with 16 NO ejectors
630 mA
Polarity reversal protection
Yes, all M12 connector connections
Degree of protection
IP 65
NFC
NFC Forum Tag type 4
1)
The power supply must correspond to the regulations in accordance with EN60204 (protected extra-low
voltage).
2)
Typical power consumption