DESCRIPTION OF FUNCTIONS
42 | EN
6.3.2.5
Control function, without continuous suction
This operating mode is the same as the “Control” operating mode but it does not switch to continuous
suction when the valve switching frequency is exceeded.
When the control shutoff is deactivated, the suction valve makes frequent adjustments.
This may destroy the ejector.
6.3.2.6
Control function with leakage monitoring, without continuous suction
This operating mode is the same as the “Control function with leakage monitoring” operating mode,
but the device does not switch to continuous suction when the permitted leakage is exceeded or when
the valve switching frequency is exceeded.
When the control shutoff is deactivated, the suction valve makes frequent adjustments.
This may destroy the ejector.