Safety 

5.1  Safety Instructions 

Local safety requirements are fully applicable. The following safety instructions are 
complimentary to the rules in force and do not supersede the latter: 

 

 

Wear safety shoes and gloves. 

 

Never exceed the maximum lifting capacity of the device. Never exceed the 

maximum lifting capacity of the crane or hoist used. Consider the weight of the 
lifting device. Observe the name plate. 

 

Do not stand below the load. Always keep clear of the load. 

 

Never carry people or animals with the load or the lifting device itself! 

 

Operate only when you can view the entire working area. Look out for other 

persons in the working area. Never manoeuvre loads above people. 

 

Do not let go of the handle whilst lifting a load. 

 

Do not pull loads to the side or drag them along with the lifting device. 

 

Do not rip loose loads that have become jammed. 

 

When there is a power failure put the load down immediately if possible. 

Immediately leave the danger area near the load. 

 

Apply suction and lift only to appropriate loads (check for stability and porosity). 

 

Always keep an eye on the pressure gauge. Never lift loads when the vacuum 

is below -0.125 bar. When the pointer of the pressure gauge moves into the red 
danger zone below -0.125 bar, put the load down immediately. 

 

When the horn blows, put the load down immediately. 

 

Land workpieces only on free, level surfaces. Otherwise they can slip away 

when you land them. 

 

Land load only when it has touched down entirely and safely. Fingers away 

from the load when you land it. Severe bruises! 

 

Always distribute load evenly on the suction surfaces. 

 

Check all seals, suction hoses and claps daily. 

Eliminate leakages before initiation. 

 

 

Caution

 

The following operating steps must be checked by a qualified mechanic 
prior to use of the device by the operating personnel. Correct faults before 
start-up.

 

5.2  Lifting Loads 

 

Warning

 

 

 

Switch the lifting device on. 

 

Position the lifting device directly above the load. Do not pull sideways. 

Distribute load evenly. 

 

Put the lifting device down on the load. It suck on by itself. 

 

Watch the pressure gauge. As soon as -0.125 bar has been reached you can 

lift the load. Never lift the load before. It would fall off. 

 

 

Caution

 

 

When lifting be sure to lift only one piece of the items to be lifted. Before lifting, 

carefully remove other pieces sticking to the one you want to lift. Use a 
screwdriver to do that. Do not separate them with your hands. Severe bruises! 

5.3  Swivelling Loads 

(only

 

M

ULTI 

...-90°)

 

Warning

 

 

Push the Button "Swivel vertically" (1) resp. "Swivel horizontally" (2). 
Do not stand in the swivelling area! 
Please pay attention by swivelling that the load does not crash against anything. 

!! Accident hazard !!

 

 

Summary of Contents for VacuMaster Multi 400-1

Page 1: ...A 30 30 01 00221 00 J Schmalz GmbH Aacher Stra e 29 D 72293 Glatten Tel 49 7443 2403 0 Fax 49 7443 2403 259 http www schmalz de e mail schmalz schmalz de Status 03 2013 Page 1 18 Please keep this manu...

Page 2: ...evices 2 Technical Data 3 Description 3 1 Components of the Lifting Device 3 2 Blower with Reversing Device 3 3 Swivelling Unit only MULTI 90 3 4 Controls 3 5 Suction boxes pads 4 Installation 4 1 Gen...

Page 3: ...Operating Manual Blower Gebl K10 DG 14 Spare Part List Blower Gebl K10 DG 14 Electrical Connection Diagram EU Conformity Declaration Special features The unit is equipped with the following special f...

Page 4: ...he operating instructions and especially the chapter Safety therein Your company must ensure by internal measures that the operators of the lifting device are properly trained that they have read and...

Page 5: ...f possible If this is not possible immediately leave the dangerous area near the load Danger The device generates a very strong suction which can draw in hair and clothing Do not look into the suction...

Page 6: ...Check all suction hoses and clamps for proper mounting if necessary retighten the clamps Checking the warning signal Switch on the lifting device Place it on a board suck the board Danger Attention O...

Page 7: ...Blower 50 Hz 3 230 400 V 0 95 kW optional 60 Hz 3 255 440 V 1 6 kW Electric swivelling motor 50 Hz 3 230 400 V 0 25 kW 60 Hz 3 250 440 V 0 25 kW Weight ca 75 kg ca 105 kg ca 105 kg ca 130 kg ca 135 k...

Page 8: ...2013 Page 8 18 3 Description 3 1 Components of the Lifting Device The parts with safety function appear in bold type Pos Description Pos Description 1 Blower 8 Switch box 2 Reversing Device 9 Clampin...

Page 9: ...00221 00 Status 03 2013 Page 9 18 The parts with safety function appear in bold type Pos Description Pos Description 1 Blower 9 Clamping lever 2 Reversing Device 10 Star grip 3 Swivelling Unit 11 Ball...

Page 10: ...A springloaded brake stops the swivelling In the beginning a thin grease residue may show on the drive shaft and air relief valve This is normal and no reason to worry 3 4 Controls The controls are mo...

Page 11: ...the supply cable with plug from the control box Connect the cable to the power supply of the crane or hoist according to local regulations This job must be done by a qualified electrician Be sure that...

Page 12: ...oads when the vacuum is below 0 125 bar When the pointer of the pressure gauge moves into the red danger zone below 0 125 bar put the load down immediately When the horn blows put the load down immedi...

Page 13: ...n activating a Release button Crushing hazard Hold both Release buttons 3 and raise the lifting device 5 5 Switch on off the back suction pad row To remove boards from racks the back suction pad row c...

Page 14: ...does not suck wrong rotation direction Check and correct connection reversing unit do not work Check control reverse jammed clean it filter get choked Replace clean filter Blower dropped out power on...

Page 15: ...n swivelling devices gearwheel cover securely fitted X X Inspect and maintain the blower and reversing unit as described in the operating instructions See operating instructions for blower and reversi...

Page 16: ...wivel Unit only MULTI 90 The oil in the gearbox of the swivel head must be changed after 10 000 operating hours or after three years whichever occurs sooner Oil capacity 0 2 litres To change the oil f...

Page 17: ...e for leaks once per month Place the suction pads on an airtight smooth surface such as a sheet of metal Switch on the vacuum blower and suck on the workpiece A vacuum of at least 0 15 bar has to be r...

Page 18: ...x load must not be exceeded 9 Guarantee spare and consumable parts This equipment is guaranteed in accordance with our General Conditions of Business This also applies to spare parts where these are o...