Vacuum switch 

 Pressure switch

 

VS-D 

Series

 

 

 

 

BA 30.30.01.00011_EN 
Status 03.2014 / Index 01 

1 / 3 

J. Schmalz GmbH, Aacher Straße 29, D-72293 Glatten 

Tel 07443/2403-0, Fax -259 

 

 

Safety 

These operating instructions contain important information on 
the use of vacuum switches. Please read them carefully and 
keep them in a safe place for future reference. 

 

You  must  read  and  understand  these  operating  instructions 
before connecting and using the vacuum switch. 

 

Always comply with these instructions and observe the safety 
notes and warnings. 

Warnings: 

  The  vacuum  switch  may  not  be  used  outside  the  specified 

performance  limits,  since  this  can  result  in  malfunctions  and/or 
destruction of the switch! 

  The vacuum switch  may not be used in explosion-hazard areas, 

since it may cause fires and explosions! 

  The switch may not be used for safety-relevant functions 

  The  switch  may  not  be  opened  for  any  purpose  (including 

repairs)! Opening the switch may damage it and may also result 
in injuries! 

  The switch may be used only with 

power supply units which provide 
a protective low voltage (PELV) and with 
reliable isolation of the supply voltage 
in accordance with EN60204. 

PELV 

 

Caution: 

  Do not carry the vacuum switch by its cable, and do not pull the cable. 

  Protect the switch against mechanical interference (tearing off). 

  Switch off the supply voltage before connecting the switch. 

  Do not expose the switch to splash-water. 

  Never  insert  any  objects  (such  as  wires,  tools,  etc.)  into  the  vacuum 

connection of the switch. 

 

1. Front panel 

 LED Output 1

LED Output 2

Up

Mode

Display

Down

 

Display: 
Preset values in setting mode. 
Vacuum level in measurement 
mode. 

The minus sign is not 
displayed when pressure 
unit bar, inHg or mmHg is 
selected (VS-V-D). 

Mode 

Button to select the different modes. 

Up & Down

 

Buttons to change settings. 

LED Output 1  
and  Output 2 

Switching indicator, 
Output 1 = red, Output 2 = green. 

2. Connecting power supply in normal operation 

After connecting the power supply, in the display panel you can 
see the presetted values. 
When connecting the power supply do not push any key. 

 

 

 

 

 

 

Type 

Selected 

pressure unit 

 

Display 

Measured 

pressure 

3.  Zero-point adjustment 

Adjust the zero-point only when the vacuum/pressure line is not 
connected. To adjust the zero-

point, push the ”Mode“-key at 

least 3 seconds. 

 

 

 

 

Display Measured 

p

atm

 

Hold for 

min. 3 sec

 

 

Zero-point 

adjusted

 

4. Clear All 

If the switch was wrongly programmed, it can be set back in 
to the factory settings. 

All stored values are cleared. To accomplish this function, 
disconnect the switch from the power supply. Whilst pushing the 
”Mode“-key” and the ”Up“-key, connect the power supply again. 

 

 

Push and hold both keys simultaneous 

After connecting the power supply, the display shows “CLA“. 
When you release the buttons, the presetted pressure unit is 
displayed by “ -bA” resp. ”bA”. 

 

 

When pushing the ”Mode“-key one time, the selected pressure 
unit is confirmed and stored. 

1x

 

 

 

To adjust an other pressure unit see paragraph 6.3 

5.  Factory settings

 

The switch is delivered with following factory settings 

Unit 

Output 1 

Output 2 

bar 

HYS, N.O. 

HYS, N.O. 

This setting can be changed (programmed).  
The programming is described in the following paragraph. 

A built-in EEPROM retains data for a period of min. 10 years. 
The data are min. 10.000 times rewritable. 
N.O = normally open, N.C. = normal closed, 
HYS = operating mode „Hysteresis mode“ 
The initial settings of the operating mode is shown  
in the table in paragraph 8. 

6.  Setting of output configuration (N.O. or N.C.) and 

pressure unit (e.g. bar). 

To adjust the output configuration and the pressure unit, push 
and hold the ”Mode”-key, the push the “Up“-key. 

 

 

 

 

 

 

 

hold

 

 

 

 

The display is alternating between 

“ou I“ and ”n.o.”

 

6.1 Selection N.O. or N.C. of output 1 

To change the setting, push ”Up”- or “Down”-key. 

 

 

 

 

 

 

 

Store the settings with the 

“Mode”-key 

1x

 

 

 

Now the display switches to the selection of output 2, 
the display changes from ”ou 2” to ”n.o.” 

6.2 Selection N.O. or N.C. of output 2 

To change the setting, 

push ”Up”- or “Down”-key. 

 

 

 

 

 

 

Store the settings with the “Mode”-key. 

1x

 

 

bar 

Now the display switches to the selection of the pressure unit. 

6.3 Adjust the pressure unit 

To change the setting, push ”Up”- or “Down”-key. 

 

 

mmHg 

 

 

kPa

 

 

 

inHg 

Store the settings with the “Mode”-key. 

1x

 

 

 

 

Possible pressure units for VS-V-D 

Unit 

bar 

mmHg 

inHg 

kPa 

Symbol 

 

 

 

 

 

Possible pressure units for VS-P10-D

 

Unit 

psi 

kgf/cm² 

MPa 

bar 

Symbol 

 

 

 

 

7.  Adjusting the operating mode 

7.1 Adjusting output 1 

Example:

 Switch VS-V-D, output 1 has the operating mode 

“Hysteresis-mode“. 
switching point: 

-0,6 bar 

hysteresis: 

0,15 bar 

Further information to the modes see paragraph 8. 

Adjusting the operating mode 

To select output 1, push ”Mode”-key 2x. 

2x

 

 

wait 2 sec  

 

 

 

After 2 seconds, the display is alternating between “ou I“ 
and the preadjusted operating mode. 

 

 

 

 

 

Push the ”Up”- or “Down”-key until “HYS“ for the desired 
switching mode „Hysteresis-mode“ is displayed. 

 

 

 

 

 

Store the settings with the “Mode”-key. 

1x

 

 

 

 

 

Setting switching point and hysteresis 

To select the switching point of output 1 push ”Mode”-key 1x. 

1x

 

 

 

wait 2 sec 

After 2 seconds, the display is alternating between “H-1“  
and the preadjusted value. 

 

 

To adjust the switching point, push the ”Up”- or “Down”-key  
until the desired value is displayed. 

 

 

 

 

 

 
Store the settings with the “Mode”-key. 

1x

 

Now the display switches to the selection of the hysteresis. 
The display is alternating between “h-1“ and the preadjusted 
value. 

 

 

To adjust the hysteresis, push the ”Up”- or “Down”-key until 
the desired value is displayed. 

 

 

 

 

 

 

Store the settings with the “Mode”-key 

1x

 

 

 

 

 

 

 

7.2 Adjusting output 2 

Example:

 Switch VS-V-D, output 2 has the operating mode 

“Window comparator mode“ 
Switching points are between -0,57 bar and -0,83 bar  
(lower margin A=-0,57, upper margin b = -0,83) 

Further information to the modes see paragraph 8. 

Adjusting the operating mode

 

To select output 2, push ”Mode”-key 4x 

4x

 

 

 

wait 2 sec 

 

 

After 2 seconds, the display is alternating between  
“ou 2“ and “HYS“. 

 

 

 

 

Push the ”Up”- or “Down”-key until “CnP“ for the desired 
switching mode “Window Comparator Mode“ is 
displayed. 

 

 

 

 

 

 

Store the settings with the “Mode”-key. 

1x

 

 

 

 

 

Adjusting the lower and the upper margin 

To select the lower margin of output 2, push ”Mode”-key 3x 

 

3x

 

 

wait 2 sec

 

 

 

After 2 seconds, The display is alternating between “A-2“ 
and the preadjusted value. 

 

 

 

 
 

Push the ”Up”- or “Down”-key until the desired value is 
displayed. 

 

 

 

 

 

 

Store the settings with the “Mode”-key. 