Technical Data
12 / 44
EN-US · 30.30.01.00956 · 03 · 05/22
4.4 Factory Settings
Parameter
VSi-V
VSi-P10
VSi-VP8
VSi-V-SA
Switching point 1
Switching point mode and
logic
Normally open two-point mode (H.no)
Switching point SP1
750 mbar
5500 mbar
–750 mbar
–750 mbar
Reset point rP1
600 mbar
5000 mbar
–600 mbar
–600 mbar
Window hysteresis Hy1/leakage
limit per sec L-1
20 mbar
100 mbar
20 mbar
20 mbar
Switch-on delay dS1,
switch-off delay dr1
0 ms
Transistor function
PNP
Switching point 2
Switching point mode and
logic
Two-point mode, normally closed (H. no)
Not
available
Switching point SP2
550 mbar
5000 mbar
5500 mbar
Reset point rP2
500 mbar
4500 mbar
5000 mbar
Window hysteresis Hy2/leakage
limit per sec L-2
20 mbar
100 mbar
20 mbar
Switch-on delay dS2,
switch-off delay dr2
0 ms
Transistor function
PNP
Display unit
mbar
Eco mode
Off
Display alignment
Standard
IO-Link device locks, extended
device locks
0
Menu PIN code, NFC PIN code
000