Summary of Contents for AES 1185

Page 1: ...hine or plant The safety monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country...

Page 2: ...ed and removable safety guards as well as emergency stop control devices Design The safety monitoring module has a dual channel structure It includes two safety relays with monitored positive action contacts The NO contacts of the relays which are wired in series build the enabling contacts 2 4 Technical data Standards IEC EN 60204 1 EN 60947 5 1 EN 60947 5 3 EN ISO 13849 1 IEC 61508 BG GS ET 14 B...

Page 3: ...brations the end position of a non contact position switch is often overrun This causes the safety monitoring module to generate an error message To avoid this the enabling delay time can be extended by removing the device cover and setting an internal bridge jumper Bridge closed enabling delay time 1 0 second Bridge closed enabling delay time 0 1 second factory setting 6 Set up and maintenance 6 ...

Page 4: ...a safety guard is opened the LED indication changes Indication yellow LED System condition 1 impulse Safety guard 1 open 2 impulses Safety guard 2 open 3 impulses Safety guard 3 open Table error indications Indication orange LED Error Cause 1 impulse Error safety guard 1 Defective supply voltage lead defective switch erroneous fitting of the switch switch only partially actuated for at least 5 s c...

Page 5: ...est DGUV Test Prüf und Zertifizierungsstelle Fachbereich Elektrotechnik Gustav Heinemann Ufer 130 50968 Köln ID n 0340 EU prototype test certificate ET 16038 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal The currently valid declaration of conformity can be downloaded from the internet at www schmersal net Place and date of issue W...

Page 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...