background image

4

Operating instructions

Safety-monitoring module

AES 1185

EN

AES 1185 - DC devices

Monitoring of three safety guards by means of position switches with 

safety function

A1

S13

S14

S22

X1

13

24 VDC

K3

K4

S1

L1

S

A

S2

S3

K1

K2

14

A2

S14

S22

S14

S22

OV

N

3

M

K3

K4

A

A

AES 1185.3 - AC devices

Monitoring of three safety guards by means of one magnetic safety 

sensor (BNS)

AES 1185

A1

S13

14

A2

S14

S22

S14

S22

3

S14

S22

X1

13

24 VAC

N

N

M

K1

K2

K3

K3

K4

K4

S1

S2

S3

L1

24 VDC

S

Key

A

Positive break

H

Start button

P

Actuated

A - C 

S

Non-contact safety sensor

8.2  Integral System Diagnostics (ISD)

The LED indication of the safety-monitoring modules shows the 

different switching conditions and errors. The following tables show the 

different switching conditions.

Tables switching condition indication

Diagnostic LED

System condition

The LED is green.

Enabling paths closed

LED flashes green

Enable delay time running,  
enabling paths opened

LED flashes yellow (2 Hz) Feedback circuit is open

If a safety guard is opened, the LED indication changes.

Indication (yellow) LED

System condition

1 impulse

 

Safety guard 1 open

2 impulses

 

Safety guard 2 open

3 impulses

 

Safety guard 3 open

Table error indications

Indication (orange) 

LED

Error

Cause

1 impulse

 

Error safety guard 1 Defective supply 

voltage lead, defective 
switch, erroneous 
fitting of the switch; 
switch only partially 
actuated* for at least 5 
s; cross-wire short

2 impulses

 

Error safety guard 2 Refer to Error safety 

guard 1

3 impulses

 

Error safety guard 3 Refer to Error safety 

guard 1

5 impulses

One or both relays 
did not close within 
the monitoring time

Too low operating 
voltage U

e; 

Defective relay

6 impulses

 

Relay not disabled 
upon the actuation 
of the switch

 May be due to contact 
welding

7 impulses

Interference signals 
at the inputs (no 
safe evaluation 
assured)

Too high capacitive or 
inductive interference 
at the input signal

*  Partial actuation: position of the switch, in which only one contact was actuated.

Deleting the error message

The error message is deleted once the fault has been rectified and after 

the connected switch has been actuated to check the various functions 

(open and then close the safety guard).

Summary of Contents for AES 1185

Page 1: ...hine or plant The safety monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country...

Page 2: ...ed and removable safety guards as well as emergency stop control devices Design The safety monitoring module has a dual channel structure It includes two safety relays with monitored positive action contacts The NO contacts of the relays which are wired in series build the enabling contacts 2 4 Technical data Standards IEC EN 60204 1 EN 60947 5 1 EN 60947 5 3 EN ISO 13849 1 IEC 61508 BG GS ET 14 B...

Page 3: ...brations the end position of a non contact position switch is often overrun This causes the safety monitoring module to generate an error message To avoid this the enabling delay time can be extended by removing the device cover and setting an internal bridge jumper Bridge closed enabling delay time 1 0 second Bridge closed enabling delay time 0 1 second factory setting 6 Set up and maintenance 6 ...

Page 4: ...a safety guard is opened the LED indication changes Indication yellow LED System condition 1 impulse Safety guard 1 open 2 impulses Safety guard 2 open 3 impulses Safety guard 3 open Table error indications Indication orange LED Error Cause 1 impulse Error safety guard 1 Defective supply voltage lead defective switch erroneous fitting of the switch switch only partially actuated for at least 5 s c...

Page 5: ...est DGUV Test Prüf und Zertifizierungsstelle Fachbereich Elektrotechnik Gustav Heinemann Ufer 130 50968 Köln ID n 0340 EU prototype test certificate ET 16038 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal The currently valid declaration of conformity can be downloaded from the internet at www schmersal net Place and date of issue W...

Page 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: