background image

For Sales and Support, Contact Walker EMD • www.walkeremd.com • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800

K. A. Schmersal GmbH

Industrielle Sicherheitsschaltsysteme

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Telefon  +49 - (0)2 02 - 64 74 - 0 

Telefax  +49 - (0)2 02 - 64 74 - 1 00

E-Mail:   info@schmersal.com

Internet:   http://www.schmersal.com

Summary of Contents for AES 2135

Page 1: ...his warning notice could lead to physical injury and or damage to the machine 1 4 Appropriate use The products described in these operating instructions are developed to execute safety related functions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the proper functionality of the entire machinery or plant The safety monitoring mo...

Page 2: ... The safety monitoring modules have a dual channel structure They include two safety relays with monitored positive action contacts The NO contacts of the relays which are wired in series build the enabling contacts 2 4 Technical data Standards IEC EN 60204 1 EN 60947 5 3 EN ISO 13849 1 IEC 61508 BG GS ET 14 BG GS ET 20 Start conditions Automatic Feedback circuit available no Start up test AES 5 n...

Page 3: ...h two NC contacts a bridge must be established between X3 and X4 In this configuration the short circuit detection becomes inoperative Conversion of the output function X5 X6 By using a bridge between X5 and X6 the output function of the additional outputs can be modified This control can also be realised when e g a PLC is running 24 VDC at terminal X6 Enable delay time X7 X8 By bridging the conne...

Page 4: ...stem condition The LED is green Enabling paths closed LED flashes yellow 0 5 Hz Enabling paths open LED flashes yellow 2 Hz Safety guard closed however no release possible causes incorrect operation only one contact actuated upon opening or voltage drop perform start up test In case of error messages the LED lights orange intermittently During these intermissions the LED flashes one up to seven ti...

Page 5: ...afety components both in its basic design and construction conforms to the applicable European Directives Place and date of issue Wuppertal October 7 2009 Authorised signature Heinz Schmersal Managing Director Name of the safety component type AES 2135 AES 2136 Description of the safety component Safety monitoring module for non contact safety switches and safety relay combi nation in connection w...

Page 6: ... 4444 Tel 203 426 7700 Fax 203 426 7800 K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Telefon 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...