background image

2

Operating instructions
Safety-monitoring module

EN

AES 2355/2356; AES 2555/2556
AES 2365/2366; AES 2565/2566

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  
the safety-monitoring module, personal hazards or damages 
to machinery or plant components cannot be excluded.  
The relevant requirements of the standard EN 1088 must  
be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages resulting 
from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-

pairs, conversions and modiications to the device are strictly forbidden; 

the manufacturer shall accept no liability for damages resulting from 

such invasive work, arbitrary repairs, conversions and/or modiications 

to the device.

2  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

AES 2

5

No.

Option

Description

3

3 enabling paths

5

5 enabling paths

5

without start-up test

6

with start-up test

AES 2

6

No.

Option

Description

3

3 enabling paths

5

5 enabling paths

5

without start-up test

6

with start-up test

Only if the information described in this operating instructions 
manual are realised correctly, the safety function and therefore 
the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these speciications apply accordingly, provided that they correspond to 

the standard version.

2.3  Destination and use

The safety-monitoring modules for integration in safety circuits are 

designed for itting in control cabinets. They are used for the safe 

evaluation of the signals of positive break position switches for safety 
functions or magnetic safety sensors on sliding, hinged and removable 
safety guards as well as emergency stop control devices.

Design

The safety-monitoring modules have a dual-channel structure. They 
include two safety relays with monitored positive action contacts. The 
NO contacts of the relays, which are wired in series, build the enabling 
contacts.

2.4  Technical data

Standards:

IEC/EN 60204-1; EN 60947-5-1; 

 

EN 60947-5-3; EN ISO 13849-1; 

 

IEC 61508; BG-GS-ET-14; 

 

BG-GS-ET-20

Start conditions

Automatic or start button

Feedback circuit available:

yes

Start-up test:

AES ...5: no; AES ...6: yes

Pull-in delay for automatic start:

adjustable 0.1 / 1.0 second

Drop-out delay in case of  
emergency stop:

50 ms

Rated operating voltage U

e

:

24 ... 230 VAC/DC

Rated operating current I

e

:

0.3 A

Rated insulation voltage U

i

:

250 V

Rated impulse withstand  

voltage U

imp

:

4 kV

Thermal test current I

the

:

6 A

Internal electronic fuse:

no

Power consumption:

5 W

Input monitoring:

Cross-wire short detection:

yes

Wire breakage detection:

yes

Earth leakage detection:

yes

Number of NC contacts:

2

Number of NO contacts:

2

Outputs:

Stop category 0:

AES 2355/6, AES 2365/6: 3
AES 2555/6, AES 2565/6: 4

Stop category 1:

0

Number of safety contacts:

AES 2355/6, AES 2365/6: 3
AES 2555/6, AES 2565/6: 4

Number of auxiliary contacts:

AES 2355/6, AES 2365/6: 0
AES 2555/6, AES 2565/6: 1

Number of signalling outputs:

2

Signalling output:

2 transistor outputs,  
Y1 + Y2 = max. 100 mA,  
p-type, short-circuit proof

Max. switching capacity  
of the safety contacts:

6 A

Utilisation category to 

 

EN 60947-5-1:

AC-15: 230 V / 3 A 
DC-13: 24 V / 2 A

Max. fuse rating:

6 A gG D-fuse

Mechanical life:

20 million operations

LED indication:

Wiring diagram

Ambient conditions:

Operating temperature:

0°C ... +55°C

Storage and transport  
temperature:

-25°C ... +70°C

Protection class:

Enclosure: IP 40
Terminals: IP 20
Wiring compartment: IP 54

Degree of pollution:

2

Fixation:

Snaps onto standard DIN rails  
to DIN EN 60715

Connection type:

Screw terminals

Min. cable section:

0.2 mm

2

Max. cable section:

2.5 mm

2

solid strand or multi-strand lead  

(including conductor ferrules)

Tightening torque:

0.6 Nm

Max. cable length:

1000 m with 0.75 mm

2

 cable

Weight:

AES 2355/6, AES 2365/6: 290 g
AES 2555/6, AES 2565/6: 300 g

Dimensions (H/W/D):

100 x 45 x 121 mm