1.6  Warning about misuse

In case of inadequate or improper use or manipulations of 

the safety-monitoring module, personal hazards or damages 

to plant components cannot be excluded The relevant 

requirements of the standards ISO 14119, EN 81-20 and  

EN 81-50 must be observed

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

AES 9107

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefore 

the compliance with the Lift Directive is maintained

2.2  Destination and use

The safety-monitoring module is used for the safe evaluation of the 

signals of positive-break position switches for safety functions or 

magnetic safety switches on sliding, hinged and removable safety 

guards The safety-monitoring module meets the requirements of  

ISO 13849-1: control category 3 / PL d

In addition to that, the requirements of EN 81-20 and EN 81-50 are 

fulfilled, which enables an evaluation of the signals of a magnetic safety 

switch for the position monitoring of the hook bar on elevator shaft doors

Design

The safety-monitoring module has a dual-channel structure It includes 

two safety relays with monitored positive action contacts The series-

wired relay contacts build the enabling path

The entire concept of the control system, in which the safety 

component is integrated, must be validated to the relevant 

standards

2.3  Technical data

Standards:

 

IEC 60947-5-3, EN 81-20, EN 81-50, IEC 60204-1 

Enclosure:

 ABS

Terminals:

 

Cage clamps

Cable section:

 

max 25 mm² (incl conductor ferrules)

Protection class:

 

Enclosure IP65 to IEC 60529

Operating voltage U

e

:

 

24 VDC ± 15%, incl 10 % residual ripple

Operating current:

 

01 A

Input resistance:

 

S13: approx. 3 kΩ; 

 

S21: approx. 1 kΩ

Outputs:

 

Relay contact 13-14: 1 enabling path  

with 2 series-wired NO contacts

Utilisation category:

 

AC-15, DC-13

Rated operating current/voltage I

e

/U

e

:

 

2 A / 250 VAC;  

2 A / 24 VDC

Switching voltage:

 

max 250 VAC

Fuse:

 

2 A quick blow

Switching capacity:

 

max 500 VA

Relay service life:

 

 

- mechanical:

 

> 20 x 10

6

 operations (without load); 

- electrical:

 

> 10

6

 operations at 2 A, cos φ = 1

Ambient temperature:

 

0 ºC … + 65 ºC

Storage and transport temperature:

 

– 25 ºC … + 70 ºC

Max cable length:

 

1000 m of 075 mm² conductor

Max switching frequency:

 

1 Hz

Resistance to vibration:

 

10 … 55 Hz; amplitude 035 mm  

+ 15% at the control circuit

Resistance to shock:

 

30 g / 11 ms

EMC rating:

 

conforming to EMC Directive

2.4  Safety classification

Standards:

 

ISO 13849-1, IEC 61508 

PL:

 d

Control Category:

 3

PFH-value:

 

10 x 10

-7

 / h 

- Note:

 

Applicable for applications with up to  

max 50,000 switching cycles / year  

and max 80 % contact load  

Diverging applications upon request

SIL:

 

suitable for SIL 2 applications

Service life:

 

20 years

3.  Mounting

3.1  General mounting instructions

The safety-monitoring module is fitted onto the shaft wall (surface 

mounting) or in the machine room by means of the integrated 

mounting holes

3.2  Dimensions

All measurements in mm

60

80

66

160

146

4.  Electrical connection

4.1  General information for electrical connection

The electrical connection may only be carried out by  

authorised personnel in a de-energised condition

Summary of Contents for AES 9107

Page 1: ...ity of the entire machine or plant The safety monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructio...

Page 2: ...ng module has a dual channel structure It includes two safety relays with monitored positive action contacts The series wired relay contacts build the enabling path The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 3 Technical data Standards IEC 60947 5 3 EN 81 20 EN 81 50 IEC 60204 1 Enclosure ABS Terminals Cage clam...

Page 3: ... change does not take place the release is blocked even when the right signals for this situation are measured at the inputs when the safety guard is closed again When the safety guard is opened the enabling path of the safety monitoring module is opened as well The circuit of the output current by the approach of the magnetic switch must only be closed when the mechanical interlock installed to t...

Page 4: ...equate use the safety monitoring module features maintenance free functionality A regular visual inspection and functional test including the following steps is recommended 1 Check the correct fixing of the safety monitoring module 2 Check the cable for damage 3 Check electrical function The device has to be integrated into the periodic check ups according to the Ordinance on Industrial Safety and...

Page 5: ...e for monitoring the BNS 260 11Z non contact door contact coded magnetic switch Year of construction See identification plate Relevant Directives Lift Directive Low Voltage Directive EMC Directive RoHS Directive 2014 33 EU 2014 35 EU 2014 30 EU 2011 65 EU Applied standards EN 81 20 2014 EN 81 50 2014 EN 60947 5 3 2013 Notified body for the prototype test TÜV Rheinland Certification body for lifts ...

Page 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: