4
Operating instructions
Safety-monitoring module
AES 9107
EN
6. Set-up and maintenance
6.1 Functional testing
The safety function of the safety-monitoring module must be tested
The following conditions must be previously checked and met:
1 Correct fitting of the safety-monitoring module
2 Fitting and integrity of the power cable
The internal fuse (on the circuit board) to protect the output current
circuit should only be fitted with a fuse of the same rating
(fine fuse 2 A fast-acting, 5x 20 mm, 250 V)
6.2 Maintenance
In the case of correct installation and adequate use, the safety-
monitoring module features maintenance-free functionality
A regular visual inspection and functional test, including the following
steps, is recommended:
1 Check the correct fixing of the safety monitoring module
2 Check the cable for damage
3 Check electrical function
The device has to be integrated into the periodic check-ups
according to the Ordinance on Industrial Safety and Health,
however at least 1 x year
Damaged or defective components must be replaced.
7. Disassembly and disposal
7.1 Disassembly
The safety monitoring module must be disassembled in the de-
energised condition only
7.2 Disposal
The safety monitoring module must be disposed of in an appropriate
manner in accordance with the national prescriptions and legislations