AES 9107

Operating instructions

Safety-monitoring module

8. EU Declaration of conformity

Place and date of issue:

Wuppertal, November 8, 2016

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

KA Schmersal GmbH & Co KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: wwwschmersalcom

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives 

Name of the component:

AES 9107

Description of the component:

Safety-monitoring module for monitoring 

the BNS 260-11Z non-contact door contact 

(coded magnetic switch)

Year of construction:

See identification plate

Relevant Directives:

Lift Directive

Low Voltage Directive

EMC-Directive

RoHS-Directive

2014/33/EU

2014/35/EU

2014/30/EU

2011/65/EU

Applied standards:

EN 81-20:2014,

EN 81-50:2014,

EN 60947-5-3:2013

Notified body for the prototype test:

TÜV Rheinland

Certification body for lifts and their safety components

der TÜV Rheinland Industrie Service GmbH

Am Grauen Stein, 51105 Köln

ID n°: 0035

EU-prototype test certificate:

01/208/4A/611300/16

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

The currently valid declaration of conformity can be  

downloaded from the internet at wwwschmersalnet

Summary of Contents for AES 9107

Page 1: ...ity of the entire machine or plant The safety monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructio...

Page 2: ...ng module has a dual channel structure It includes two safety relays with monitored positive action contacts The series wired relay contacts build the enabling path The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 3 Technical data Standards IEC 60947 5 3 EN 81 20 EN 81 50 IEC 60204 1 Enclosure ABS Terminals Cage clam...

Page 3: ... change does not take place the release is blocked even when the right signals for this situation are measured at the inputs when the safety guard is closed again When the safety guard is opened the enabling path of the safety monitoring module is opened as well The circuit of the output current by the approach of the magnetic switch must only be closed when the mechanical interlock installed to t...

Page 4: ...equate use the safety monitoring module features maintenance free functionality A regular visual inspection and functional test including the following steps is recommended 1 Check the correct fixing of the safety monitoring module 2 Check the cable for damage 3 Check electrical function The device has to be integrated into the periodic check ups according to the Ordinance on Industrial Safety and...

Page 5: ...e for monitoring the BNS 260 11Z non contact door contact coded magnetic switch Year of construction See identification plate Relevant Directives Lift Directive Low Voltage Directive EMC Directive RoHS Directive 2014 33 EU 2014 35 EU 2014 30 EU 2011 65 EU Applied standards EN 81 20 2014 EN 81 50 2014 EN 60947 5 3 2013 Notified body for the prototype test TÜV Rheinland Certification body for lifts ...

Page 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: