4

Operating instructions

Safety-monitoring module

AES 9107

EN

6.  Set-up and maintenance

6.1  Functional testing

The safety function of the safety-monitoring module must be tested 

The following conditions must be previously checked and met:

1 Correct fitting of the safety-monitoring module

2 Fitting and integrity of the power cable

The internal fuse (on the circuit board) to protect the output current 

circuit should only be fitted with a fuse of the same rating  

(fine fuse 2 A fast-acting, 5x 20 mm, 250 V)

6.2  Maintenance

In the case of correct installation and adequate use, the safety-

monitoring module features maintenance-free functionality

A regular visual inspection and functional test, including the following 

steps, is recommended:

1 Check the correct fixing of the safety monitoring module

2 Check the cable for damage

3 Check electrical function

The device has to be integrated into the periodic check-ups 

according to the Ordinance on Industrial Safety and Health, 

however at least 1 x year

Damaged or defective components must be replaced.

7.  Disassembly and disposal

7.1  Disassembly

The safety monitoring module must be disassembled in the de-

energised condition only

7.2  Disposal

The safety monitoring module must be disposed of in an appropriate 

manner in accordance with the national prescriptions and legislations

Summary of Contents for AES 9107

Page 1: ...ity of the entire machine or plant The safety monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructio...

Page 2: ...ng module has a dual channel structure It includes two safety relays with monitored positive action contacts The series wired relay contacts build the enabling path The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 3 Technical data Standards IEC 60947 5 3 EN 81 20 EN 81 50 IEC 60204 1 Enclosure ABS Terminals Cage clam...

Page 3: ... change does not take place the release is blocked even when the right signals for this situation are measured at the inputs when the safety guard is closed again When the safety guard is opened the enabling path of the safety monitoring module is opened as well The circuit of the output current by the approach of the magnetic switch must only be closed when the mechanical interlock installed to t...

Page 4: ...equate use the safety monitoring module features maintenance free functionality A regular visual inspection and functional test including the following steps is recommended 1 Check the correct fixing of the safety monitoring module 2 Check the cable for damage 3 Check electrical function The device has to be integrated into the periodic check ups according to the Ordinance on Industrial Safety and...

Page 5: ...e for monitoring the BNS 260 11Z non contact door contact coded magnetic switch Year of construction See identification plate Relevant Directives Lift Directive Low Voltage Directive EMC Directive RoHS Directive 2014 33 EU 2014 35 EU 2014 30 EU 2011 65 EU Applied standards EN 81 20 2014 EN 81 50 2014 EN 60947 5 3 2013 Notified body for the prototype test TÜV Rheinland Certification body for lifts ...

Page 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: