Operating instructions

Solenoid interlock

AZM 161 AS

EN

Warning about misuse

In case of improper use or manipulation of the safety 

switchgear, personal hazards or damages to machinery 

or plant components cannot be excluded. The relevant 

requirements of the standard ISO 14119 must be observed.

1.6  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories. 

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

AZM 161 

➀ ➁

-AS 

➂➃➄

No. Option

Description

Z

Solenoid interlock monitored

B

Actuator monitored

BZ

Combined actuator/solenoid interlock monitoring 

ST1

Connector in the middle

ST2

Connector at the right-hand side

Latching force 5 N

R

Latching force 30 N

Power to unlock

A

Power to lock

Magnet supply from AS-Interface

P

Magnet supply 24 VDC (AUX)

Manual release

N

Emergency release

T

Emergency exit

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefore 

the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Purpose

The AZM 161 AS is designed for use with AS-Interface Safety at Work. 

The safety switchgears are classified according to  

ISO 14119 as type 2 interlocking devices.

The different variants can be used as safety switch with interlocking 

function either as solenoid interlock for the position monitoring and 

locking of movable safety guards.

Interlocks with power to lock principle may only be used in 

special cases after a thorough evaluation of the accident risk, 

since the safety guard can be opened immediately on failure 

of the power supply or upon activation of the main switch.

If the risk analysis indicates the use of a monitored interlock 

then a variant with the monitored interlock is to be used, 

labelled with the   symbol.

The actuator monitoring variant (B) is a safety switch with an 

interlock function for process protection.

The safety function of the safety switchgear consists of safely switching 

off the code transmission when the safety guard is opened and 

maintaining the safe switched off condition for as long as the safety 

guard is open.

An AS-Interface Safety at Work component functions on the basis of 

an individual code generator (8 x 4 bit). This safety code is cyclically 

transmitted over the AS-i network and monitored by the safety monitor. 

The component status can be evaluated through a PLC with  

AS-Interface master. The safety-related functions are enabled by 

means of the AS-i safety monitor.

LED display

The LED's have the following meaning (to EN 62026-2):

Yellow LED:

Channel 1 / AS-i SaW bit 0,1

LED green/red

AS-i duo LED:

AS-Interface supply voltage/ 

AS-Interface communication error or  

slave address 

=

 0 or periphery error

Yellow LED:

Channel 2 / AS-i SaW bit 2,3

Manual release

A manual release is available as a mounting tool and in the event of a 

power failure in case the power to unlock principle is used. 

The manual release is realised by turning the triangular key by 180°, 

so that the locking bolt is pulled into the unlocking position. Please 

ensure that jamming by external influence on the actuator is avoided. 

The normal locking function is only restored after the triangular key has 

been returned to its original position. After being put into operation, the 

manual release must be secured by installing the plastic cover, which is 

included in delivery.

Triangular key TK-M5 (101100887) available as accessory.

Summary of Contents for AZM 161 AS

Page 1: ...ons listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety inst...

Page 2: ...riants can be used as safety switch with interlocking function either as solenoid interlock for the position monitoring and locking of movable safety guards Interlocks with power to lock principle may...

Page 3: ...on SaW AS interface outputs Bit 0 magnet control solenoid interlock Bit 1 Bit 3 no function Parameter port P0 actuator identified P1 solenoid interlock locked P2 magnet voltage in tolerance range P3 e...

Page 4: ...soiling in the used opening is avoided Unused actuator openings must be sealed with slot sealing plugs The safety component and the actuator must be permanently fit ted to the safety guards and protec...

Page 5: ...any time in which case the safety outputs are reactivated The safety guard must not be opened The redundancy and the Safety guard closed signal are not tested in this configuration To test these cond...

Page 6: ...0 1 1 Unlocking blocked 0 ON ON SaW code Flashes 1 1 1 1 HC1 AS i half code 1 AS i SaW bit 0 1 AZM 161 Z ST AS Z variant power to unlock spring operated locking System condition Magnet input AS i D O...

Page 7: ...ding the following steps is recommended 1 Check for a secure installation of the actuator and the switch 2 Remove particles of dust and soiling 3 Check cable entry and connections Adequate measures mu...

Page 8: ...the component Interlocking device with electromagnetic interlock for safety functions with integrated AS i Safety at Work Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42...

Reviews: