AZM 161 AS
Operating instructions
Solenoid interlock
EN
6. Set-up and maintenance
6.1 Functional testing
The safety function of the safety components must be tested.
The following conditions must be previously checked and met:
1. Check the switch enclosure for damage
2. Check for a secure installation of the actuator and the switch
3. Check the integrity of the cable entry and connections
6.2 Maintenance
A regular visual inspection and functional test, including the following
steps, is recommended:
1. Check for a secure installation of the actuator and the switch
2. Remove particles of dust and soiling
3. Check cable entry and connections
Adequate measures must be taken to ensure protection
against tampering either to prevent tampering of the safety
guard, for instance by means of replacement actuators.
Damaged or defective components must be replaced.
7. Disassembly and disposal
7.1 Disassembly
The safety switchgear must be disassembled in a de-energised
condition only.
7.2 Disposal
The safety switchgear must be disposed of in an appropriate manner in
accordance with the national prescriptions and legislations.