1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-

gear, personal hazards or damages to machinery or plant 

components cannot be excluded when safety switchgear is 

used. The relevant requirements of the standard ISO 14119 

must be observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.5  Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .5

4.2  Contact variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

7  EU Declaration of conformity

x.000 / 10.2016 / v

.A.   -   101212802-EN / C / 2016-09-30 / 

AE-Nr

. 6583

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

Summary of Contents for AZM 170 series

Page 1: ...sions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident pre...

Page 2: ...ith the Machinery Directive is maintained 2 2 Special versions For special versions which are not listed in the order code below 2 1 these specifications apply accordingly provided that they correspond to the standard version 2 3 Destination and use The solenoid interlock has been designed to prevent in conjunction with the control part of a machine movable safety guards from being opened before h...

Page 3: ...ISO 13849 1 Envisaged structure Basically applicable up to Cat 1 PL c With 2 channel usage and fault exclusion mechanism applicable up to Cat 3 PL d with suitable logic unit B10d NC contact 2 000 000 B10d NO contact at 10 ohmic contact load 1 000 000 Service life 20 years If a fault exclusion to the 1 channel mechanics is authorised MTTF B d x x h s h 3600 d 10d op op op n 0 1 x nop t cycle Determ...

Page 4: ... ordering suffix 2197 AZM 170 ST with connectors 2 x 4 poles A or B coding ø 4 2 24 22 15 20 M12 M12 37 90 18 31 4 60 17 15 5 23 8 2 AZM 170ST with connectors 1x 4 poles 1 x 8 poles ø 4 2 24 22 15 58 18 16 16 90 18 31 4 76 5 17 16 23 8 2 18 Actuator Straight actuator B1 Angled actuator B5 30 22 20 23 2 33 10 4 3 4 5 30 22 20 8 23 12 2 36 13 7 5 4 3 Flexible actuator B6L Flexible actuator B6R 22 32...

Page 5: ...r B6L B6R b a a b b a a b b a a b The B6L or B6R actuators are set to the smallest radius in factory To increase the radius the setting screws a b must be turned by means of a hexagonal key A F 2 5 mm 4 Electrical connection 4 1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de energised condition If the risk analysis in...

Page 6: ...5 6 7 8 13 11 12 14 1 NO 1 NC 2 NC ordering suffix 11 02 1 NO 1 NC 2 NC ordering suffix 11 02 11 13 14 12 A1 41 31 32 42 A2 31 41 42 32 A1 A2 1 2 3 4 13 11 12 14 1 2 3 4 5 6 7 8 31 41 42 32 A1 A2 1 2 3 4 13 11 12 14 1 2 3 4 5 6 7 8 A1 11 13 14 12 41 31 32 42 A2 AZM 170 I with connector Power to unlock Power to lock 1 NO 1 NC ordering suffix 11 1 NO 1 NC ordering suffix 11 A1 A2 14 22 21 32 13 1 1 ...

Page 7: ...k and the actuator 2 Check the integrity of the cable entry and connections 3 Check the switch enclosure for damage 5 2 Maintenance A regular visual inspection and functional test including the following steps is recommended 1 Check for tight installation of the actuator and the switch 2 Remove particles of dust and soiling 3 Check cable entry and connections Adequate measures must be taken to ens...

Page 8: ... 14119 2014 Person authorized for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal September 7 2016 Authorised signatu...