background image

8

EN

AZM170I-C-EN

Operating instructions

Solenoid interlock

AZM 170 I

7.  EU Declaration of conformity

The currently valid declaration of conformity can be  

downloaded from the internet at www.schmersal.net.

Name of the component:

AZM 170 I

Type:

See ordering code

Description of the component:

Interlocking device with electromagnetic  

interlock for safety functions

Relevant Directives:

Machinery Directive

EMC-Directive

RoHS-Directive

2006/42/EC

2014/30/EU

2011/65/EU

Applied standards:

DIN EN 60947-5-1:2010,

DIN EN ISO 14119:2014

Person authorized for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

K. A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Phone:  +49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00

E-Mail: info@schmersal.com

Internet: http://www.schmersal.com

Place and date of issue:

Wuppertal, September 7, 2016

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives. 

Summary of Contents for AZM 170 series

Page 1: ...sions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident pre...

Page 2: ...ith the Machinery Directive is maintained 2 2 Special versions For special versions which are not listed in the order code below 2 1 these specifications apply accordingly provided that they correspond to the standard version 2 3 Destination and use The solenoid interlock has been designed to prevent in conjunction with the control part of a machine movable safety guards from being opened before h...

Page 3: ...ISO 13849 1 Envisaged structure Basically applicable up to Cat 1 PL c With 2 channel usage and fault exclusion mechanism applicable up to Cat 3 PL d with suitable logic unit B10d NC contact 2 000 000 B10d NO contact at 10 ohmic contact load 1 000 000 Service life 20 years If a fault exclusion to the 1 channel mechanics is authorised MTTF B d x x h s h 3600 d 10d op op op n 0 1 x nop t cycle Determ...

Page 4: ... ordering suffix 2197 AZM 170 ST with connectors 2 x 4 poles A or B coding ø 4 2 24 22 15 20 M12 M12 37 90 18 31 4 60 17 15 5 23 8 2 AZM 170ST with connectors 1x 4 poles 1 x 8 poles ø 4 2 24 22 15 58 18 16 16 90 18 31 4 76 5 17 16 23 8 2 18 Actuator Straight actuator B1 Angled actuator B5 30 22 20 23 2 33 10 4 3 4 5 30 22 20 8 23 12 2 36 13 7 5 4 3 Flexible actuator B6L Flexible actuator B6R 22 32...

Page 5: ...r B6L B6R b a a b b a a b b a a b The B6L or B6R actuators are set to the smallest radius in factory To increase the radius the setting screws a b must be turned by means of a hexagonal key A F 2 5 mm 4 Electrical connection 4 1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de energised condition If the risk analysis in...

Page 6: ...5 6 7 8 13 11 12 14 1 NO 1 NC 2 NC ordering suffix 11 02 1 NO 1 NC 2 NC ordering suffix 11 02 11 13 14 12 A1 41 31 32 42 A2 31 41 42 32 A1 A2 1 2 3 4 13 11 12 14 1 2 3 4 5 6 7 8 31 41 42 32 A1 A2 1 2 3 4 13 11 12 14 1 2 3 4 5 6 7 8 A1 11 13 14 12 41 31 32 42 A2 AZM 170 I with connector Power to unlock Power to lock 1 NO 1 NC ordering suffix 11 1 NO 1 NC ordering suffix 11 A1 A2 14 22 21 32 13 1 1 ...

Page 7: ...k and the actuator 2 Check the integrity of the cable entry and connections 3 Check the switch enclosure for damage 5 2 Maintenance A regular visual inspection and functional test including the following steps is recommended 1 Check for tight installation of the actuator and the switch 2 Remove particles of dust and soiling 3 Check cable entry and connections Adequate measures must be taken to ens...

Page 8: ... 14119 2014 Person authorized for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal September 7 2016 Authorised signatu...