Operating instructions
Solenoid interlock
AZM201
EN
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
1.6 Warning about misuse
In case of improper use or manipulation of the safety
switchgear, personal hazards or damages to machinery
or plant components cannot be excluded. The relevant
requirements of the standard ISO 14119 must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages
resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary
repairs, conversions and modifications to the device are strictly
forbidden, the manufacturer shall accept no liability for damages
resulting from such invasive work, arbitrary repairs, conversions and/or
modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
AZM201
➀
-
➁
-
➂
-T-
➃
-
➄
No. Option
Description
➀
Z
Solenoid interlock monitored
B
Actuator monitored
➁
Standard coding
I1
Individual coding
I2
Individual coding, re-teaching enabled
➂
SK
Screw terminals
CC
Cage clamps
ST2
Connector plug M12, 8-pole
➃
1P2PW
1 p-type diagnostic output and
2 safety outputs, p-type
(combined diagnostic signal: guard system closed
and interlock engaged)
SD2P
serial diagnostic output and 2 p-type safety outputs
➄
Power to unlock
A
Power to lock
Actuator
suitable for
AZ/AZM201-B1-…
Sliding safety guards
AZ/AZM201-B30-…
Hinged safety guards
AZ/AZM201-B40-…
hinged-doors with overlapping folds
Only if the information described in this operating instructions
manual are realised correctly, the safety function and therefore
the compliance with the Machinery Directive is maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Comprehensive quality insurance to 2006/42/EC
Schmersal is a certified company to appendix X of the Machinery
Directive. As a result, Schmersal is entitled to autonomously conduct
the conformity assessment procedure for the products listed in
Appendix IV of the MD without involving a notified body. The prototype
test certificates are available upon request or can be downloaded from
the Internet at www.schmersal.com.
2.4 Purpose
The non-contact, electronic safety switchgear is designed for
application in safety circuits and is used for monitoring the position and
locking of movable safety guards.
The safety switchgears are classified according to ISO 14119
as type 4 interlocking devices. Designs with individual coding
are classified as highly coded.
The different variants can be used as safety switch with interlocking
function either as solenoid interlock.
If the risk analysis indicates the use of a monitored interlock
then a variant with the monitored interlock is to be used,
labelled with the symbol.
The actuator monitoring variant (B) is a safety switch with an
interlock function for process protection.
The safety function consists of safely switching off the safety outputs
when the safety guard is opened and maintaining the safe switched off
condition of the safety outputs for as long as the safety guard is open.
Interlocks with power to lock principle may only be used in
special cases after a thorough evaluation of the accident
risk, since the safety guard can be opened immediately on
failure of the power supply or upon activation of the main
switch.
Series-wiring
Series-wiring can be set up. The risk time is not altered by wiring in
series. The number of components is only limited by the external cable
protection according to the technical data and the line loss. Series-
wiring of up to 31 AZM201…-SD components with serial diagnostics
is possible. In devices with the serial diagnostics function (ordering
suffix -SD), the serial diagnostics connections are wired in series and
connected to a SD Gateway for evaluation purposes. Wiring examples
for series-wiring, refer to appendix.
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level. If multiple safety switchgears are involved in
the same safety function, the PFH values of the individual
components must be added.
The entire concept of the control system, in which the safety
component is integrated, must be validated to the relevant
standards.